dc.contributor.advisor | Ülker, Hayriye Esra | |
dc.contributor.author | Çelik, Ayşe Canan Tutku | |
dc.date.accessioned | 2020-12-10T09:34:11Z | |
dc.date.available | 2020-12-10T09:34:11Z | |
dc.date.submitted | 2017 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/236427 | |
dc.description.abstract | Bu çalışmanın amacı, kavite restorasyonunda kullanılan 4 farklı bulk fill kompozit rezinin fare fibroblast (L929) ve Klonal SV40 Large T-antijeniyle transfekte edilmiş sığır pulpa hücrelerinin (tSPTH) canlılıkları üzerine etkilerinin değerlendirilmesidir.Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent, Schaan, Lihtenştayn), SonicFill (KerrCorp, Orange, CA, ABD), everX Posterior (GC Europe, Lueven, Belçika) ve Filtek Bulk Fill (3M ESPE, Seefeld, Almanya) kompozit rezinler üretici firmanın talimatları doğrultusunda standart teflon halkalar içine yerleştirildi ve polimerize edildi. Örnekler 24 saat serum içeren kültür ortamında saklandı. L929 ve Klonal SV 40 Large T-antijeni ile transfekte edilmiş sığır pulpa hücreleri 96 kuyucuklu hücre kültür kaplarına alındı ve 24 saat 37°C'de inkübe edildi. Canlılık değerlendirme testleri için, L929 ve sığır pulpa hücreleri 24 saat materyal ekstraktı içeren kültür ortamına maruz bırakıldı. Hücre canlılığı sırasıyla MTT ve XTT metotlarıyla değerlendirildi. Veriler one-way ANOVA analiziyle istatistiksel olarak değerlendirildi.L929 hücreleri üzerinde; SonicFill ve Filtek Bulk Fill kompozit rezinlerinin orijinal ekstraktları ve 1:2, 1:4, 1:8 konsantrasyonları ile negatif kontrol grubunun hücre canlılık oranları arasındaki fark istatistiksel olarak anlamlı bulundu (p<0.05). tSPTH üzerinde ise; Tetric EvoCeram Bulk Fill kompozit rezininin orijinal ekstaktı ve 1:2, 1:4, 1:16, 1:32 konsantrasyonları, SonicFill ve everX Posterior kompozit rezinlerinin sadece orijinal ekstraktı, Filtek Bulk Fill kompozit rezininin orijinal ekstraktı ve 1:2, 1:4, 1:8, 1:16 konsantrasyonlarıyla negatif kontrol grubunun hücre canlılık oranları arasındaki fark istatistiksel olarak anlamlı bulundu (p<0.05).Filtek Bulk Fill kompozit rezin grubunun her iki hücre üzerinde de en düşük hücre canlılığı gösterdiği ve buna bağlı olarak en fazla sitotoksik etkiyi gösteren materyal olduğu tespit edildi. Bu çalışmada veriler 2 boyutlu in vitro hücre kültürü testleri yapılarak elde edilmiştir. Kliniğe daha yakın veriler elde edebilmek için 3 boyutlu hücre kültürü testleri ve in vivo çalışmalar da yapılmalıdır.Anahtar kelimeler: Bulk fill, biyouyumluluk, sitotoksisite | |
dc.description.abstract | The aim of this study was to evaluate the cytotoxic effects of four bulk fill composites on L929 and transfected bovine pulp derived with SV 40 Large T-antigen cells.Tetric EvoCeram Bulk Fill (Ivoclar-Vivadent, Schaan, Liechenstein), SonicFill (Kerr Corp., Orange, CA, USA), everX Posterior (GC Europe, Lueven, Belgium) and Filtek Bulk Fill (3M ESPE, Seefeld, Germany) composite resins specimens were prepared according to manufacturers' with using standard teflon matrix and polymerized. Specimens stored in culture medium with serum for 24 h. L929 and transfected bovine pulp derived with SV 40 Large T-antigen cells were seeded into 96-well plate and incubated for 24 h at 37oC. For evaluation of cell viability, cells were exposed to extracts of materials for 24h. Cell viability was evaluated with in order of MTT and XTT methods. Results were statistically analyzed by one-way ANOVA.On the L929 cells, the difference between the original extract and 1:2, 1:4, 1:8 concentrations of SonicFill and Filtek Bulk Fill composite resins and the cell viability of the negative control group was statistically significant (p<0.05). On transfected bovine pulp derived with SV Large T antigen, the original extract and 1:2, 1:4, 1:16, 1:32 concentrations of the Tetric EvoCeram Bulk Fill composite resin, original extract of the SonicFill and everX Posterior composite resins, original extract and 1: 2, 1: 4, 1: 8, 1:16 of the Filtek Bulk Fill composite resin and cell viability of the negative control group were statistically significant (p<0.05).The Filtek Bulk Fill composite resin group showed the lowest cell viability on both cells and the most cytotoxic effect was also observed in this group. In this study, data were obtained by conducting 2-dimensional in vitro cell culture tests. In order to obtain closer data to the clinic, 3-dimensional cell culture tests and in vivo studies should be performed.Key words: Bulk fill,biocompatibility, cytotoxicty | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Bulk fill kompozitlerin biyoyuyumluluğunun değerlendirilmesi | |
dc.title.alternative | Biocompatibility evaluation of bulk fill composites | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Restoratif Diş Tedavisi Anabilim Dalı | |
dc.subject.ytm | Dental restoration | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Composite materials | |
dc.subject.ytm | Cytotoxicity | |
dc.subject.ytm | Composite resins | |
dc.subject.ytm | Dental bonding | |
dc.subject.ytm | Dental cements | |
dc.identifier.yokid | 10146573 | |
dc.publisher.institute | Diş Hekimliği Fakültesi | |
dc.publisher.university | SELÇUK ÜNİVERSİTESİ | |
dc.type.sub | dentistThesis | |
dc.identifier.thesisid | 464299 | |
dc.description.pages | 71 | |
dc.publisher.discipline | Diğer | |