Show simple item record

dc.contributor.advisorÖzcura, Fatih
dc.contributor.authorTaşdemir Yiğitoğlu, Sila
dc.date.accessioned2020-12-10T06:42:25Z
dc.date.available2020-12-10T06:42:25Z
dc.date.submitted2018
dc.date.issued2019-04-16
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/213468
dc.description.abstractAmaç: Katarakt cerrahisi sonrası hastaların ön segment parametrelerindeki değişimleri değerlendirmek.Materyal ve Metod: Kütahya Sağlık Bilimleri Üniversitesi Tıp Fakültesi Göz Hastalıkları Anabilim Dalında ileriye dönük olarak planlanan çalışmaya sistemik hastalığı olmayan ve katarakt cerrahisi planlanan 82 hasta dahil edildi. Hastalar aksiyel uzunluğa (AU) göre 2 gruba ayrıldı (Grup 1: AU<23,25 mm n:42, Grup 2: AU>23,25 mm, n:40). Hastaların merkezi kornea kalınlığı (MKK), kornea hacmi (KH), ön kamara hacmi (ÖKH), ön kamara derinliği (ÖKD), iridokorneal açı (İKA), limbus limbus mesafesi (LLM), kornea asferisitesi (Q) ve pupil çapı (PÇ) değerleri ameliyat öncesi ve ameliyat sonrası birinci hafta ve birinci ayda Pentacam cihazıyla değerlendirildi.Bulgular: Hastaların ortalama yaşı 64,4±10,0 yıl ve 46'sı (%56,1) erkek, 36'sı (%43,9) kadındı. Tüm popülasyonda ameliyat öncesi değere göre MKK ameliyat sonrası 1. haftada anlamlı olarak yüksek bulundu. KH, ÖKH, ÖKD ve İKA ameliyat sonrası 1. hafta ve 1. ayda ameliyat öncesine göre anlamlı olarak artış gösterdi. PÇ ameliyat sonrası 1. haftada anlamlı olarak azalmakla birlikte, ameliyat sonrası 1. ayda anlamlı fark göstermedi. LLM ve Q değerlerinde ameliyat sonrası anlamlı değişim gözlenmedi. Gruplar arası parametrelerin değişim farkı incelendiğinde Grup 1 yani kısa AU sahip olan gözlerde ÖKH ve İKA'daki artışın anlamlı olarak daha fazla olduğu saptandı.Sonuç: Katarakt cerrahisi sonrasında KH, ÖKH, ÖKD ve İKA'da anlamlı artış olmaktadır. Özellikle kısa AU sahip gözlerde ÖKH ve İKA'daki değişim daha da fazladır.Anahtar kelimeler: aksiyel uzunluk, katarakt, ön segment parametreleri, pentacam
dc.description.abstractPurpose: Evaluating the anterior segment parameters of the patients after cataract surgery.Materials and Methods: This prospective study included 82 patients who had no any systemic diseases and planned cataract surgery at the Department of Ophthalmology, Kütahya Medical Sciences University School of Medicine. Patients were divided into two groups (Group 1: AL<23.25 mm n:42, Group 2: AL> 23.25 mm, n:40) according to axial length (AL). Central corneal thickness (CCT), corneal volume (CV), anterior chamber volume (ACV), anterior chamber depth (ACD), iridocorneal angle (ICA), white-to-white (WTW) distance, corneal asphericity (Q) and pupil diameter (PD) values of the patients were evaluated with Pentacam device before and one week and one month after the surgery.Results: Average age of the patients is 64.4±10,0 years and 46 (56.1%) of them were male, 36 (43.9%) of them were female. CCT was significantly higher one week after the surgery compared to preoperative values in all population. CV, ACV, ACD, and ICA were significantly higher one week and one month after the surgery, compared to preoperative values. PD has significantly decreased one week after the surgery but did not significantly different at one month postoperatively. There were no significantly differences in WTW and Q values postoperatively. ACV and ICA were more significantly increased in patients had shorter AL (group 1) when the analyzed absolute difference of the parameters. Conclusions: CV, ACV, ACD, and ICA were significantly increased after cataract surgery. The alteration in ACV and ICA were more prominent especially in eyes had shorter AL.Keywords: anterior segment parameters, axial length, cataract, pentacamen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectGöz Hastalıklarıtr_TR
dc.subjectEye Diseasesen_US
dc.titleKatarakt cerrahisi yapılan hastalarda ön segment parametrelerinin değerlendirilmesi
dc.title.alternativeEvaluation of anterior segment parameters in patientsafter cataract surgery
dc.typedoctoralThesis
dc.date.updated2019-04-16
dc.contributor.departmentGöz Hastalıkları Anabilim Dalı
dc.subject.ytmEye
dc.subject.ytmEye diseases
dc.subject.ytmCataract
dc.subject.ytmCataract extraction
dc.subject.ytmSurgery-eye
dc.subject.ytmAnterior chamber
dc.subject.ytmEquipment and supplies
dc.subject.ytmEquipment and supplies-hospital
dc.identifier.yokid10210210
dc.publisher.instituteTıp Fakültesi
dc.publisher.universityKÜTAHYA SAĞLIK BİLİMLERİ ÜNİVERSİTESİ
dc.type.submedicineThesis
dc.identifier.thesisid516923
dc.description.pages72
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess