dc.description.abstractAmaç: Bu çalışmanın amacı; yeni nesil tek tabaka halinde uygulanabilen bulk fill kompozit rezinlerin QTH ve LED ışık cihazları ile polimerize edilerek dönüşüm değerlerinin ve mikrosertlik düzeylerinin karşılaştırılmasıdır.Materyal ve Metot: Çalışmamızda 6 farklı bulk fill kompozit rezin; SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) ve kontrol grubu olarak 1 adet mikrohibrit tipte Filtek Z250 (3M ESPE) kullanılımştır. Kompozit rezinlerden 7 mm çapında 2 ve 4 mm kalınlığında disk şeklinde örnekler hazırlanarak, LED (Elipar S10, 3M ESPE) ve QTH (Hilux, Benlioğlu) ışık cihazları kullanılarak polimerize edilmiştir. Örneklerin 24 saat 37 °C'de bekletilmesinin ardından FTIR-ATR (Perkin Elmer Spectrum Two) ile dönüşüm yüzdeleri belirlenmiş ve ardından Knoop sertlik cihazı (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA) ile sertlik ölçümleri yapılmıştır. Verilerin istatistiksel değerlendirmesinde çok yönlü Varyans Analizi ve Tukey çoklu karşılaştırma testi uygulanmıştır (p<0.05).Bulgular: Tüm kompozit grupları içerisinde en yüksek dönüşüm derecesini 2 mm'de LED ışık cihazı ile Filtek Z250 gösterirken, en düşük değeri 4 mm'de QTH ile Beautifil Bulk Flowable göstermiştir. 2 mm LED ile polimerize edilmiş X-tra Fil alt ve üst yüzey sertlik ortalamalarında en yüksek değeri gösterirken, 4 mm'de QTH ile polimerize edilmiş Filtek Bulk Flowable üst yüzey, Filtek Z250 ise alt yüzey sertlik ortalamalarında en düşük değeri göstermişlerdir.Sonuç: Çalışmada kullanılan kompozit rezinlerin dönüşüm dereceleri ve sertlikleri örneklerin kalınlığından ve ışık cihazlarından etkilenmiştir. Bulk Fil kompozit rezinlerin dönüşüm dereceleri ile sertlik değerleri arasında ilişki olmadığı gösterilmiştir. Bütün kalınlıklarda LED ile polimerize edilen örneklerin dönüşüm ve mikrosertlik değerleri QTH'tan yüksek çıkmıştır.
dc.description.abstractPurpose: The purpose of this study is to compare the conversion values and microhardness levels of new generation bulk fill composite resins that can be applied in one layer by polymerizing them with QTH and LED light devices.Material and Method: 6 different bulk fill composite resins SDR (Dentsply), Sonic Fill (Kerr), X-tra Fil (VOCO), Beautifil Bulk Restorative (Shofu), Beautifil Bulk Flowable (Shofu), Filtek Bulk Flowable (3M ESPE) and 1 microhybrid type Filtek Z250 (3M ESPE) as the control group were used in our study. Samples with a diameter of 7 mm and thickness of 2 and 4 mm in the form of discs were prepared from the composite resins and they were polymerized by using LED (Elipar S10, 3M ESPE) and QTH (Hilux, Benlioğlu) light devices. After the samples were kept for 24 hours at 37 °C, their conversion degree were found with FTIR-ATR (Perkin Elmer Spectrum Two) and their hardness measurements were made with Knoop hardness device (Buehler MMT-3 Digital microhardness tester; Lake Bluff, IL, USA). In the statistical assessment of the data, Multi-Way analysis of variance and Tukey multi comparison test were applied (p<0.05). Results: Of all the composite groups, while Filtek Z250 showed the highest conversion degree with LED light device at 2 mm, Beautifil Bulk Flowable showed the lowest conversion degree with QTH at 4 mm. While X-tra Fil polymerized with 2 mm LED showed the highest degree in bottom and top surface hardness averages, Filtek Bulk Flowable polymerized with QTH at 4 mm showed the lowest degree in top surface hardness averages and Filtek Z250 polymerized with QTH at 4 mm showed the lowest degree in bottom surface hardness averages.Conclusion: Conversion degrees and hardness of composite resins used in the study were influenced by the thickness of the samples and by the light devices. No association was found between the conversion degrees and hardness values of bulk fill composite resins. In all thicknesses, conversion and microhardness values of samples polymerized with LED were found to be higher than those of QTH.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleHalojen ve led ile polimerize edilmiş bulk fill kompozit rezinlerin dönüşüm derecesi ve mikrosertlik değerlerinin karşılaştırmalı olarak incelenmesi
dc.title.alternativeComparative analysis of conversion degrees and microhardness values of bulk fill composite resins polymerized with different light devices
dc.typedoctoralThesis
dc.date.updated2019-09-20
dc.contributor.departmentRestoratif Diş Tedavisi Anabilim Dalı
dc.subject.ytmHalogens
dc.subject.ytmLight emitting diode
dc.subject.ytmComposite resins
dc.subject.ytmMicrohardness
dc.identifier.yokid10246165
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityONDOKUZ MAYIS ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid549717
dc.description.pages102
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess