dc.contributor.advisor | Doğanay, Selim | |
dc.contributor.author | Taşar, Ahmet | |
dc.date.accessioned | 2020-12-07T11:10:30Z | |
dc.date.available | 2020-12-07T11:10:30Z | |
dc.date.submitted | 2008 | |
dc.date.issued | 2018-08-06 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/137286 | |
dc.description.abstract | Amaç: Psödoeksfolyatif sendrom (PES) ve psödoeksfolyatif glokomlu (PEG) olgularda ön segment parametrelerini Pentacam-Scheimpflug yöntemi ile değerlendirmek.Gereç ve Yöntem: PES saptanan (Grup 1) 53 hastanın (25 erkek, 28 bayan) 80 gözü, PEG saptanan (Grup 2) 57 hastanın (30 erkek, 27 bayan) 80 gözü ve kontrol grubu (Grup 3) olarak alınan 45 hastanın (25 erkek, 20 bayan) 80 gözü Pentacam ile değerlendirildi. Pentacam ile elde edilen ÖKD, ÖKH, ÖKA, MKK, pupilla çapı ve merkezi 3 mm, 5 mm ve 7 mm'deki kornea hacim değerleri tüm gruplar arasında karşılaştırıldı.Bulgular: ÖKD değerleri açısından PEG grubunda ÖKD değerleri kontrol grubuna göre anlamlı şekilde düşük bulunurken (p<0.05), PES grubu ve kontrol grubu arasında ÖKD değerleri arasında fark saptanmadı (p>0.05). ÖKH, ÖKA, MKK, pupilla çapı ve merkezi 3 mm, 5 mm ve 7 mm'deki kornea hacim değerleri açısından PES, PEG ve kontrol grubu arasında anlamlı fark saptanmadı. (p>0.05)Sonuç: PEG'li hastaların ÖKD değerleri sağlıklı bireylere göre daha düşük izlenmektedir. PES'li hastalarda ise ÖKD değerleri sağlıklı bireylerle benzerdir. Pentacam ile saptanan ÖKH, ÖKA, MKK, pupilla çapı ve kornea hacim değerleri açısından, PES'li ve PEG'li hastalar ile sağlıklı bireyler arasında fark yoktur.Anahtar kelimeler: Psödoeksfolyatif sendrom, psödoeksfolyatif glokom, Pentacam, ön segment parametreleri | |
dc.description.abstract | Purpose: To evaluate PES and PEG patient?s anterior segment parameters with Pentacam-Scheimpflug.Material and Method: 53 patients (25 male, 28 female) 80 eyes with PES (Group 1), 57 patients (30 male, 27 female) 80 eyes with PEG (Group 2), and 45 control group patients (25 male, 20 female), (Group 3) 80 eyes were evaluated with Pentacam. ACD, ACV, ACA, CCT, pupilla diameters, and cornea volume values on central 3 mm, 5 mm, 7 mm were compared between groups..Results: However, ACD values in PEG group is significantly lower than the control group (p<0.05), there was no difference between PES group and the control group in means of ACD values (p>0.05). There was no significant difference between PES, PEG, and control group in mean values of ACV, ACA, CCT, pupilla diameter and cetral 3 mm, 5 mm, and 7 mm central cornea volume.Conclusion: PEG patients ACD values are lower than those of healthy individuals. PES patient?s ACD values are similar to healthy individuals. There is no significant difference in means of ACV, ACA, CCT, pupilla diameter and cornea volume values on central 3 mm, 5 mm, 7 mm between patients with PES, PEG, and healthy individuals.Key Words: Pseudoexfoliative syndrome, pseudoexfoliative glaucoma, Pentacam, anterior segment parameters | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Göz Hastalıkları | tr_TR |
dc.subject | Eye Diseases | en_US |
dc.title | Psödoeksfolyatif sendrom ve Psödoeksfolyatif glokomlu olgularda ön segment parametrelerinin Pentacam-Scheimpflug yöntemi ile değerlendirilmesi | |
dc.title.alternative | Evaluation of Pseudoexfoliative syndrome and pseudoexfoliative glaucoma patient?s anterior segment parameters with Pentacam-Scheimpflug method | |
dc.type | doctoralThesis | |
dc.date.updated | 2018-08-06 | |
dc.contributor.department | Göz Hastalıkları Anabilim Dalı | |
dc.subject.ytm | Pseudoexfoliation syndrome | |
dc.identifier.yokid | 324240 | |
dc.publisher.institute | Tıp Fakültesi | |
dc.publisher.university | İNÖNÜ ÜNİVERSİTESİ | |
dc.type.sub | medicineThesis | |
dc.identifier.thesisid | 225090 | |
dc.description.pages | 65 | |
dc.publisher.discipline | Diğer | |