Show simple item record

dc.contributor.advisorBağış, Bora
dc.contributor.authorMustafaoğlu, Emine
dc.date.accessioned2020-12-07T09:02:24Z
dc.date.available2020-12-07T09:02:24Z
dc.date.submitted2019
dc.date.issued2020-02-13
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/119603
dc.description.abstractBu çalışmanın amacı non-termal plazmanın farklı cam seramiklerin farklı rezin simanlarla bağlantı kuvvetine etkisini değerlendirmektir. Çalışmada, IPS e-MAX(EC) ve Vitamark II(VM) CAD/CAM bloklarından elde edilen her materyal grubundan 80 örnek olmak üzere toplam 160 örnek, uygulanacak yüzey işlemi ve siman kombinasyonuna göre 16 gruba ayrıldı: VR1 (VM, HF+Primer, Rely x Ultimate (RXU)+Single bond), VR2 (VM, Primer, RXU+Single bond), VRP1(VM, HF+Plazma+ Primer, RXU+Single bond ),VRP2 (VM, Plazma+ Primer, RXU+Single bond ), VZ1 (VM, HF+Primer, Zenitcem), VZ2 (VM, Primer, Zenitcem), VZP1 (VM, HF+Plazma+Primer, Zenitcem), VZP2 (VM, Plazma+Primer, Zenitcem), LR1 (IPS e-MAX, HF+Primer, Rely x Ultimate (RXU)+Single bond), LR2 (IPS e-MAX, Primer, RXU+Single bond), LRP1 (IPS e-MAX, HF+Plazma+Primer, RXU+Single bond ), LRP2 (IPS e-MAX , Plazma+ Primer, RXU+Single bond ), LZ1 (IPS e-MAX , HF+Primer, Zenitcem), LZ2 (IPS e-MAX , Primer, Zenitcem), LZP1 (IPS e-MAX , HF+Plazma+Primer, Zenitcem), LZP2 (IPS e-MAX , Plazma+Primer, Zenitcem). Örneklere farklı yüzey işlemleri uygulandı. Ardından örnekler kompozit silindirlere simante edildi ve (37°C, %100 nemli, 24 saat) etüvde bekletildi. Makaslama bağlanma dayanımları universal test cihazında ölçüldü. Örnek yüzeyleri Taramalı Elektron Mikroskopunda (SEM,Scanning Electron Microscope) incelendi. İstatistiksel analiz için üç yönlü ANOVA testi uygulandı. Plazma uygulanan seramik gruplarında bağlanma dayanımı istatistiksel olarak anlamlı olmasa da kırılma tipleri adezivden çok miks türünde gözlendi. HF ve primer yüzey işlemi uygulanan seramik gruplarında Single Bond+RXU, Zenitcem rezin siman uygulamalarına göre daha yüksek bağlanma dayanımı gösterdi. HF seramik ve siman tipinden bağımsız olarak bağlanma dayanımını arttırdı. Primer ve rezin siman uygulanan seramik yüzeylerde plazma öncül uygulamasının bağlantı dayanımına etkisi yoktur. Anahtar kelimeler: Non-termal plazma, CAD/CAM, seramik, rezin siman
dc.description.abstractThe aim of this study was to evaluate the effect of non-thermal plasma on the bond strength of different glass ceramics with different resin cements. In this study, 160 samples, 80 samples from each material group obtained from IPS e-MAX (EC) and Vitamark II (VM) CAD / CAM blocks, were divided into 16 groups according to the combination of surface treatment and cement: VR1 (VM, HF+Primer, Rely x Ultimate (RXU)+Single bond), VR2 (VM, Primer, (RXU+Single bond)(SRX)), VRP1 (VM, HF+Plasma+Primer, RXU+Single bond), VRP2 (VM, Plasma+Primer, RXU + Single bond), VZ1 (VM, HF+Primer, Zenitcem (Z)), VZ2 (VM, Primer, Zenitcem), VZP1 (VM, HF+Plasma+Primer, Zenitcem), VZP2 (VM, Plasma+Primer, Zenitcem), LR1 (IPS e-MAX, HF+Primer, Rely x Ultimate (RXU)+Single bond), LR2 (IPS e-MAX, Primer, RXU+Single bond), LRP1 (IPS e-MAX, HF+Plasma+Primer, RXU+Single bond, LRP2 (IPS e-MAX, Plasma+Primer, RXU+Single bond), LZ1 (IPS e-MAX, HF+Primer, Zenitcem), LZ2 (IPS e-MAX, Primer, Zenitcem), LZP1 (IPS e-MAX, HF+Plasma+Primer, Zenitcem), LZP2 (IPS e-MAX, Plasma+Primer, Zenitcem). Different surface treatments were applied to the samples. The samples were then cemented to composite cylinders and waited in an oven (37 °C, 100% moist, 24 hours). Shear bond strengths were measured in universal testing machine. Sample surfaces were examined with SEM (Scanning Electron Microscope). Three-way ANOVA test was used for statistical analysis. Although bond strength was not statistically significant in plasma treated ceramic groups, fracture types were observed in mix type rather than adhesive. Single bond+RXU showed higher bond strength in ceramic groups treated with HF and primer surface treatment than Zenitcem resin cement. HF increased the bonding strength regardless of ceramic and cement type. Plasma pretreatment has no effect on the bond strength on ceramic surfaces where primer and resin cement are applied.Key words: Non-thermal plasma, CAD/CAM, ceramic, resin cementen_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleNon-termal plazmanın cam seramiklerin rezin simanlarla bağlantı kuvvetine etkisinin değerlendirilmesi
dc.title.alternativeEvaluation of the effect of non-thermal plasma on the bonding strength of glass ceramics with resin cements
dc.typedoctoralThesis
dc.date.updated2020-02-13
dc.contributor.departmentProtetik Diş Tedavisi Anabilim Dalı
dc.subject.ytmCAD/CAM
dc.subject.ytmDental materials
dc.subject.ytmDental porcelain
dc.subject.ytmDental cements
dc.subject.ytmDental bonding
dc.subject.ytmDental stress analysis
dc.subject.ytmPlasma
dc.identifier.yokid10258213
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityİZMİR KATİP ÇELEBİ ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid552719
dc.description.pages104
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess