Show simple item record

dc.contributor.advisorKara, Yusufali
dc.contributor.authorDüzcan, Abdullah
dc.date.accessioned2020-12-07T08:26:04Z
dc.date.available2020-12-07T08:26:04Z
dc.date.submitted2019
dc.date.issued2020-02-16
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/114538
dc.description.abstractBir sistemi değerlendirirken enerjetik olarak değerlendirmek yeterli değildir. Sistemde oluşan kayıpların yerini, miktarını belirlemek için ekserji analizi yapılmaktadır. Bu çalışmada Bursa Orhaneli Termik Santrali'nin enerji, ekserji, eksergoekonomik ve eksergoçevresel analizi yapılmıştır. Ekserji analizinde fiziksel ve kimyasal ekserji dikkate alınmış, potansiyel ve kinetik ekserjiler ihmal edişmiştir. Ekserji analizi ile sistem bileşenlerinin ekserji verimleri ve ekserji yıkımları hesaplanmıştır. En yüksek ve en düşük ekserji verimlerine sahip ekipmanlar %92,41 ile orta basınç türbini ve %8,89 ile kondenserdir. Ekserji analizi sonucuna göre, iyileştirme potansiyeli en yüksek eleman kondenser olarak belirlenmiştir. Eksergoekonomik analizde de SPECO metodu kullanılmış ve her ekserji akımına karşılık gelen maliyet değerleri hesaplanmıştır. Eksergoekonomik analiz sonucuna göre, yüksek basınç türbinine gönderilen buharın birim ekserji maliyeti ve ekserji maliyeti sırasıyla 22,19 $/GJ ve 28.264 $/h olarak hesaplanmıştır. Sistemde kullanılan her ekipmanın yaşam döngüsü analizi (LCA) yapılmıştır. Yaşam döngüsü analizinden alınan sonuçlar ekserji akımlarına aktarılarak eksergoçevresel analiz gerçekleştirilmiştir. Analiz sonucuna göre, çevreye en zararlı ekipman kondenser olarak tespit edilmiştir.
dc.description.abstractWhen evaluating a system, it is not enough to evaluate it energetically. Exergy analysis is performed to determine the location and amount of losses in the system. In this study, energy, exergy, exergoeconomic and exergoenvironmental analysis of Bursa Orhaneli Thermal Power Plant were carried out. In exergy analysis, physical and chemical exergy were taken into consideration and potential and kinetic exergy were neglected. Exergy efficiency and exergy destructions of system components were calculated by exergy analysis. Equipments with the highest and lowest exergy yields are medium pressure turbines with 92.41% and condensers with 8.89%. According to the results of exergy analysis, the element with the highest improvement potential was determined as condenser. SPECO method was used in exergoeconomic analysis and cost values corresponding to each exergy flow were calculated. According to exergoeconomic analysis, unit exergy cost and exergy cost of steam sent to high pressure turbine were calculated as $ 22.19/GJ and $ 28,264/h, respectively. Life cycle analysis (LCA) of each equipment used in the system was performed. The results of the life cycle analysis were transferred to exergy flows and exergoenvironmental analysis was performed. According to the results of the analysis, the most harmful equipment to the environment was identified as a condenser.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectEnerjitr_TR
dc.subjectEnergyen_US
dc.titleOrhaneli Termik Santralinin eksergoekonomik ve eksergoçevresel analizi
dc.title.alternativeExergoeconomic and exergoenvironmental analysis of Orhaneli Power Plant
dc.typemasterThesis
dc.date.updated2020-02-16
dc.contributor.departmentMakine Mühendisliği Anabilim Dalı
dc.subject.ytmExergoeconomical analysis
dc.identifier.yokid10277641
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityBURSA TEKNİK ÜNİVERSİTESİ
dc.identifier.thesisid567316
dc.description.pages64
dc.publisher.disciplineDiğer