Show simple item record

dc.contributor.advisorAydın, Işıl
dc.contributor.authorGüneri, Ayşe
dc.date.accessioned2020-12-07T08:24:26Z
dc.date.available2020-12-07T08:24:26Z
dc.date.submitted2012
dc.date.issued2018-08-06
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/114332
dc.description.abstractMetal tayininde alevli atomik absorpsiyon spektrofotometresi (FAAS) oldukça sık kullanılan bir yöntemdir. Atom tuzakları gelitirilerek FAAS tekniinin duyarlılıı son yıllarda giderek arttırılmaktadır. Atom tuzakları kullanımı ile FAAS tekniinin gözlenebilme sınırı mg/L seviyesinden ng/mL düzeyine indirilmitir. Yarıklı kuvars tüp (SQT), bu atom tuzaklarından biridir. Bakırın FAAS ile tayininde yarıklı kuvars tüp (SQT) kullanarak duyarlı bir metot gelitirmeyi amaçlayan bu çalıma 5 adımdan olumaktadır. Birinci adımda FAAS ile direk analizler gerçekletirilmitir. kinci adımda SQT, FAAS?ye bir aparat olarak monte edilerek analizler yapılmıtır. SQT kullanmanın amacı, analit atomlarını SQT yüzeyinde tutarak ölçüm bölgesinde kalma sürelerini artırmak ve böylece duyarlılık artıı elde etmektir. Bu adımda birinci adıma göre yaklaık 2.21 kat duyarlılık artıı elde edilmitir. Üçüncü adımda SQT-ATFAAS ortamında analizler gerçekletirilmitir. Bu adımda, aleve gönderilen analit SQT yüzeyinde belirli bir süre toplanır. Daha sonra aleve düük hacimde metil izobütilketon (MIBK) gönderilerek analit atomlarının hızla SQT yüzeyinden uzaklatırılmaları salanır. Dördüncü adımda ise SQT?nin yüzeyi bazı metaller ile kaplanmıtır. En yüksek absorbans deeri tungsten kaplı SQT ile elde edilmitir. W kaplı SQT-AT-FAAS de duyarlılık artıının daha fazla olduu gözlenmitir. Ayrıca her bir adımda asetilen akı hızı, örnek akı hızı, asit konsantrasyonu gibi parametreler optimize edilmitir. Beinci adımda da interfer çalımaları yapılmıtır. Metodun analitiksel doruluu 1643e National?Institute of Standard & Technolgy SRM ile kontrol edildi. Uygulama olarak çeitli bölgelerden çıkarılan ve ticari amaçlı satılan içme sularının analizleri yapıldı. Analiz sonuçları Dünya Salık Örgütü (WHO) 1999 Avrupa Birlii (EC) 1998 ve Türk Standartları Enstitüsü (TSE) 266/2005 yönetmenliklerinde izin verilen konsantrasyon deerleri ile kıyaslandı. Analizi yapılan sulardaki bakır konsantrasyonun uygun olduu görüldü.Anahtar Kelimeler: Bakır, çme Suyu, FAAS, Yarıklı Kuvars Tüp (SQT)
dc.description.abstractFlame Atomic Absortion Spectrometry (FAAS) is a constantly used method for detection of metals. In the recent years atom trapping have been improved to increase sensitive of tecnique. The detection limit of FAAS technique was reduced to ng/mL level through the agency of atom trapping while it was mg/mL. Slotted of Quartz Tube (SQT) is one of these atom trappings. In this study, a sensitive method was developed by using SQT for determination of copper by FAAS method. SQT was used five different ways for this thesis. The first step of analysis was carried out directly by FAAS. Secondly, SQT as apparatus installed to the FAAS. It was aimed to increase stay time of copper atoms in the atomization region, it was observed about 2,21times increase in sensitivity. SQT-AT-FAAS analysis was carried out in the third step. In this step, analyte atoms are collected on the SQT surface in a certain time. Then the low volume of methyl isobutyl ketone (MIBK) sent to the analyte atoms in SQT surface are rapidly removed from of is provided. The optimum parameters were obtained. In the fourth step, some of the metals is covered with SQT surface. The highest absorbance value was obtained with coated tungsten. W coated SQT-AT-FAAS is higher sensitivity than the others. In addition, acetylene flow rate and sample flow rate at each step are optimized parameters such as acid concentration. Interfer studies were carried out in the fifth step. The accuracy of the system's 1643 National-Institute of Standard & Technolgy was checked with standard reference material. The commercial drinking waters are purchased from markets in Turkey and its were analyzed by these methods. The results of analysis compared with the World Health Organization (WHO), in 1999 the European Union (EC) 1998 and the Turkish Standards Institute (TSE) 266/2005. Analysis results of the copper values of the waters were found to be within the limit values. Key Words: Copper, Drinking Water, FAAS, Slotted Quartz Tube (SQT).en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectKimyatr_TR
dc.subjectChemistryen_US
dc.titleBakır tayininde atom tuzaklı atomik absorpsiyon spektrometresi metodunun kullanılması ve yöntemin interfer çalışmaları
dc.title.alternativeDeterminaton of copper with interference studies by atom trapping-atomic absorption spectrometry method
dc.typemasterThesis
dc.date.updated2018-08-06
dc.contributor.departmentKimya Anabilim Dalı
dc.identifier.yokid458138
dc.publisher.instituteFen Bilimleri Enstitüsü
dc.publisher.universityDİCLE ÜNİVERSİTESİ
dc.identifier.thesisid335500
dc.description.pages92
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess