Yapay yaşlandırma işleminin ve polimerizasyon derinliğinin farklı ışık kaynakları ile polimerize edilen bulk fill kompozitlerdeki artık monomer miktarına etkisi
dc.contributor.advisor | Karadaş, Muhammet | |
dc.contributor.author | Hatipoğlu, Ömer | |
dc.date.accessioned | 2020-12-06T14:20:09Z | |
dc.date.available | 2020-12-06T14:20:09Z | |
dc.date.submitted | 2017 | |
dc.date.issued | 2020-03-31 | |
dc.identifier.uri | https://acikbilim.yok.gov.tr/handle/20.500.12812/103671 | |
dc.description.abstract | Amaç: Bu çalışmanın amacı farklı ışık kaynakları ile farklı kalınlıkta polimerize edilmiş ve yapay yaşlandırma işlemine maruz bırakılmış 5 farklı bulk-fill kompozit rezinden (Filtek Bulk Fill Flowable, Sonic Fill 2, Surefil SDR Flow, Venus Bulk Fill, Tetric N-Ceram Bulk Fill) ve 1 adet konvansiyonel kompozit rezinden (Filtek Z250) açığa çıkan monomer miktarının incelenmesi ve elde edilen monomerlerin kompozit materyaller arasında karşılaştırılmasıdır.Materyal ve Metot: LED (Light Emitting Diode) ya da QTH (Quartz Tungsten Halogen) ışık cihazı kullanılarak 5 mm çapında hem 2 mm hem de 4 mm kalınlıkta kompozit diskler hazırlandı. Üretilen kompozit örnekler %75 etanol/su solüsyonu içeren cam viyallere aktarıldı ve sonra cam viyaller iki gruba ayrıldı. Kontrol grubunda olan cam viyaller üç farklı zaman diliminde (0-1 gün, 1-3 gün ve 3-7 gün) 37 0C'de etüvde bekletildi. Termal siklus grubunda bulunan örnekler kontrol grubunda belirlenen üç zaman dilimine denk gelecek süre kadar termal siklusa maruz bırakıldı (0-1 gün: 1500; 1-3 gün: 3000; 3-7 gün: 6000). Her bir zaman diliminde alınan ekstraksiyon örneklerindeki monomerler HPLC cihazında ölçüldü. Elde edilen veriler tekrarlanan ölçümlü varyans analizi ve tukey çoklu karşılaştırma testi (p<0,05) ile analiz edildi.Bulgular: Bis-GMA, TEGDMA, UDMA ve Bis-EMA monomerleri sırasıyla Tetric N Ceram Bulk Fill, Sonic Fill 2, SDR ve Venus Bulk Fill kompozitlerinden en fazla miktarda açığa çıktı. 1. gün en yüksek seviyede monomer elüsyona uğrarken, zamanla monomer elüsyonunun azaldığı tespit edildi. Termal siklus uygulaması artıkVIImonomer elüsyonunu artırdı ve bazı zaman periyotlarında monomerlerin sitotoksik düzeye ulaştığı belirlendi. İlk 24 saat hariç ışık kaynakları arasında anlamlı bir farklılık görülmedi. Artan kalınlıkla birlikte açığa çıkan Bis-GMA, TEGDMA, Bis-EMA monomer miktarındaki en fazla artış Sonic Fill 2 kompozitte, UDMA monomer miktarındaki en fazla artış ise Filtek Z250 kompozitinde tespit edildi.Sonuç: Monomer elüsyonunun büyük bir kısmı ilk 24 saatte gerçekleşti ve zamanla açığa çıkan monomer miktarı azaldı. Kompozit örneklerin kalınlığı 2 mm'den 4 mm'ye çıkartıldığı zaman açığa çıkan monomer miktarının oranı kullanılan kompozite göre değişkenlik gösterdi. Termal siklus işleminden sonra elde edilen monomer miktarı kompozit materyalin kalınlığı ve yapısına bağlıydı. Farklı ışık kaynakları kompozitlerden açığa çıkan monomer miktarını genellikle etkilemedi. | |
dc.description.abstract | Aim: The purpose of this study is to investigate the amount of monomer that is released from five different bulk-fill composite resins (Filtek Bulk Fill Flowable, Sonic Fill 2, Surefil SDR Flow, Venus Bulk Fill, Tetric N-Ceram Bulk Fill) and 1 conventional composite resin (Filtek Z250) exposed to artificial aging and polymerized at different thicknesses with different light sources and to compare composite materials with each other.Material and Method: Composite disks of both 2 mm and 4 mm thickness and with a diameter of 5 mm were prepared by using LED or QTH device. The resulting composite samples were transferred to glass vials containing 75% ethanol / water solution, and then the glass vials were divided into two groups. The glass vials in the control group were incubated at 37 ° C in three different time periods (0-1 days, 1-3 days and 3-7 days). The samples in the thermal cycle group were exposed to the thermal cycle (0-1 days: 1500; 1-3 days: 3000; 3-7 days: 6000) for the period corresponding to the three time periods specified in the control group. The monomers in the extractions samples taken at each time point were measured on an HPLC instrument. The obtained data were analyzed by repeated measures of variance analysis and tukey multiple comparison test (p <0.05).Results: Bis-GMA, TEGDMA, UDMA and Bis-EMA were released from Tetric N Ceram Bulk Fill, Sonic Fill 2, SDR and Venus Bulk Fill composites at maximum amount, respectively. On the first day the monomers were eluted at the highest level,IXwhile the monomer elution decreased over time. The application of the thermal cycle increased residual monomer elution and it was observed that the monomers reached cytotoxic levels in some time periods. There was no significant difference between light sources except the first 24 hours. The highest increase in the amount of Bis-GMA, TEGDMA, Bis-EMA monomer that was released with increasing thickness was observed in Sonic Fill 2 composites. The highest increase in the amount of UDMA monomer was detected in the Filtek Z250 composite.Conclusion: The majority of the monomer elution occurred during the first 24 hours and the amount of monomer that was released over time diminished. When the thickness of composite samples was increased from 2 mm to 4 mm, the proportion of the amount of monomers released varied according to the composite used. The amount of monomer obtained after thermal cycling operation was dependent on the thickness and structure of the composite material. Different light sources generally did not affect the amount of monomer released from the composites. | en_US |
dc.language | Turkish | |
dc.language.iso | tr | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | Attribution 4.0 United States | tr_TR |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject | Diş Hekimliği | tr_TR |
dc.subject | Dentistry | en_US |
dc.title | Yapay yaşlandırma işleminin ve polimerizasyon derinliğinin farklı ışık kaynakları ile polimerize edilen bulk fill kompozitlerdeki artık monomer miktarına etkisi | |
dc.title.alternative | Effect of artificial aging process and depth of curing on the amount of residual monomer in bulk fill composites polymerized with different light sources | |
dc.type | doctoralThesis | |
dc.date.updated | 2020-03-31 | |
dc.contributor.department | Restoratif Diş Tedavisi Anabilim Dalı | |
dc.subject.ytm | Artificial aging | |
dc.subject.ytm | Polymerization | |
dc.subject.ytm | Dental materials | |
dc.subject.ytm | Composite resins | |
dc.subject.ytm | Chromatography-high pressure-liquid | |
dc.subject.ytm | Monomers | |
dc.identifier.yokid | 10144269 | |
dc.publisher.institute | Diş Hekimliği Fakültesi | |
dc.publisher.university | RECEP TAYYİP ERDOĞAN ÜNİVERSİTESİ | |
dc.type.sub | dentistThesis | |
dc.identifier.thesisid | 466405 | |
dc.description.pages | 161 | |
dc.publisher.discipline | Diğer |