Show simple item record

dc.contributor.advisorGüler, Çiğdem
dc.contributor.authorKüçükaslan, Didem
dc.date.accessioned2020-12-06T13:08:08Z
dc.date.available2020-12-06T13:08:08Z
dc.date.submitted2019
dc.date.issued2020-10-14
dc.identifier.urihttps://acikbilim.yok.gov.tr/handle/20.500.12812/101891
dc.description.abstractAmaç: Bu çalışma, pit ve fissür örtücü materyallerinden farklı zaman periyotlarındasalınan artık monomer miktarlarını belirlemek amacı ile gerçekleştirilmiştir.Gereç ve Yöntem: Çalışma 12-15 yaşları arasında daimi dişlenme dönemindeki 35hasta üzerinde yürütülmüştür. Hastalar çalışmada kullanılan fissür örtücülere görerastgele beş eşit gruba (Grup 1: GC Fuji TRIAGE, Grup 2: Fissurit FX, Grup 3:ClinproTM Sealant, Grup 4: Helioseal ve Grup 5: Aegis) ayrılmıştır (n=7, alfa 0,05,güç 0,95). Hastalardan alınan tükürük örneklerinde farklı zaman periyotlarında(işlem öncesi, işlem sonrası, işlemden 1 saat sonra, işlemden 24 saat sonra) salınanartık monomerler (TEGDMA, UDMA, Bis-GMA) yüksek basınçlı sıvıkromatografisi (HPLC) ile tespit edilmiştir. İstatistiksel analizler tek yönlü varyansanalizi, Tukey HSD ve Friedmann testleri kullanılarak yapılmıştır.Bulgular: Toplam artık monomer salınımı açısından fissür örtücüler arasındaistatistiksel olarak anlamlı bir farklılık görülmüştür (p˂0,001). GC Fuji TRIAGEhariç diğer tüm fissür örtücülerden yalnızca `işlem sonrası` zaman periyodunda artıkmonomer salınımının gerçekleştiği gözlenmiştir. TEGDMA ve Bis-GMAmonomerlerinin en yüksek salınım değeri Helioseal'de görülürken, UDMAmonomerinin en yüksek salınım değeri Aegis'de görülmüştür. Değerlendirilen tümartık monomerlerin en düşük salınım değeri ise Fissurit FX'de tespit edilmiştir.Sonuçlar: Çalışmamızın sınırları dahilinde, doldurucu oranı yüksek olan fissürörtücülerden artık monomer salınımının düşük olduğu görülmüştür. Sadece fissürörtücü uyguladıktan sonra artık monomer salınımının tespit edilmesi, test edilen pitve fissür örtücülerin güvenle kullanılabileceğini göstermektedir. Bununla birlikte,fissür örtücülerin polimerizasyonu sonrası oksijen inhibisyon tabakasını kaldırmayayönelik ilave önlemler alınmalıdır.
dc.description.abstractAim: This study was carried out to determine the amount of residual monomersreleased at different time periods from different pits and fissure sealants.Material ve Method: The study was carried out on 35 patients in the permanentdentition, between 12-15 years of age. The patients were randomly divided into fiveequal groups (Group 1: GC Fuji TRIAGE, Group 2: Fissurit FX, Group 3: ClinproTMSealant, Group 4: Helioseal and Group 5: Aegis) according to fissure sealant used inthis study (n=7, alpha level of 0.05, and Power of 0.95). In the saliva samples takenfrom the patients, residual monomers (TEGDMA, UDMA and Bis-GMA) released atdifferent time periods (pre-treatment, post-treatment, 1 hour after the treatment, 24hours after the treatment) were determined by high pressure liquid chromatography(HPLC). Statistical analyzes were performed using One-Way Anova, Tukey HSDand Friedmann tests.Result: There was a statistically significant difference between fissure sealants fortotal residual monomer release (p˂0.001). It was observed that all fissure sealantshave monomer release only in the `post- treatment` time period, except GC FujiTRIAGE. The highest release value of TEGDMA and Bis-GMA monomers was seenin Helioseal while the highest release value of UDMA monomer was seen in Aegis.The lowest release value of all the residual monomers evaluated was determined inFissurit FX.Conclusion: Within the limitations of this study, it was observed that residualmonomer release was low from fissure sealants with high filling rates. Residualmonomer release detectioned only after applying the fissure sealant shows that testedpit and fissure sealers can be used safely. However, additional measures should betaken to remove the oxygen inhibition layer after polymerization of the fissuresealants.en_US
dc.languageTurkish
dc.language.isotr
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution 4.0 United Statestr_TR
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectDiş Hekimliğitr_TR
dc.subjectDentistryen_US
dc.titleFarklı fissür örtücülerden artık monomer salınımının değerlendirilmesi
dc.title.alternativeEvaluation of residual monomer release from different fissure sealants
dc.typedoctoralThesis
dc.date.updated2020-10-14
dc.contributor.departmentÇocuk Diş Hekimliği Anabilim Dalı
dc.subject.ytmMonomers
dc.subject.ytmPedodontics
dc.subject.ytmnull
dc.subject.ytmPit and fissure sealants
dc.identifier.yokid10217516
dc.publisher.instituteDiş Hekimliği Fakültesi
dc.publisher.universityORDU ÜNİVERSİTESİ
dc.type.subdentistThesis
dc.identifier.thesisid594292
dc.description.pages126
dc.publisher.disciplineDiğer


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess